| Truck Boxes |
 |
- Sandblast to obtain a surface profile of 1 to 1.5 mils complying with the standard SSPC-SP6 (commercial blast).
- Apply one coat of EP-Guard Epoxy Primer 1500 Series for a minimal dry film thickness of 3 mils.
- Topcoat with Sil-Urethane 2800 Series for a minimal dry film thickness of 3 mils.
|
|
| Salt Spreaders |
 |
- Sandblast to obtain a surface profile of 1 to 1.5 mils complying with the standard SSPC-SP6 (commercial blast).
- Apply two coats of Anti-Corrosion Primer MC-4390 for a minimal dry film thickness of 5 mils (interior and exterior).
- Topcoat the interior of the box only, with two coats of one Component Amber Shield MC-4509.
- Topcoat the exterior with two coats of Sil-Urethane 2800 Series to obtain a dry film thickness of 3 mils minimum.
|
|
| Locomotives |
 |
- Sandblast to obtain a surface profile of 1 to 1.5 mils complying with the standard SSPC-SP6 (commercial blast).
- Apply one coat of EP-Guard 1500 Series for a dry film thickness of 3 mils.
- Topcoat with Sil-Urethane 2800 Series for a dry film thickness of 3 mils.
|
|
| Potable Water Tanks |
 |
Exterior
- Sandblast to obtain a surface profile of 1.5 mils complying with the standard SSPC-SP5 (white metal blast).
- Apply two coats of Anti-Corrosion Primer MC-4390 to obtain a minimal dry film thickness of 8 mils.
- Topcoat with Sil-Urethane 2800 Series to obtain a dry film thickness of 3 mils.
Interior
- Sandblast to obtain a surface profile of 1 to 1.5 mils complying with the standard SSPC-SP5 (white metal blast).
- Apply one coat of EP-Guard White Epoxy Primer 1553 to obtain a dry film thickness of 3 mils.
- Topcoat with EP-Guard Grey Epoxy Primer 1552 to obtain a dry film thickness of 3 mils.
|
|
|